[email protected]
+44 20 3371 7320 Mon - Sat: 9:00 AM - 6:00 PM
Home All Products Spectrophotometer Atomic Absorption Spectrophotometer LD-LAAS-A22
Atomic Absorption Spectrophotometer LD-LAAS-A22

Atomic Absorption Spectrophotometer LD-LAAS-A22

SKU: LD-LAAS-A22

Atomic Absorption spectrophotometer comes with flame, graphite furnace and hydride generation system to meet different customer demand. It is provided with deuterium hollow cathode lamp to eliminate the interference of molecular absorption and Titanium Burner to improve the analysis efficiency and accuracy of the flame. The autosampler has integrated graphite furnace design with high-precision syringes to enter volume as minimum as 0.5μl with intelligent online dilution and concentration function. It has great applications research and medicine, environmental science and other industries.

  • ✓ High precision automatic optical system
  • ✓ Graphite furnace temperature control
  • ✓ High technical indicators
  • ✓ Deuterium lamp for background correction system
  • ✓ Polymer automization chamber
  • ✓ Powerful, intelligent user-friendly design
  • ✓ Automatic analysis & Sampler
Also available in:
Wavelength range : 190 - 900 nm Wavelength range : 180 - 900 nm Wavelength range : 180 – 900 nm Wavelength range : 180 – 900 nm Wavelength range : 190 nm ~ 900 nm Working spectral range : 190 to 900 nm
BurnerFull titanium combustion head, 50 mm or 100 mm general combustion head
Detectorimported photomultiplier tube
NebulizerAtomizer efficient glass atomizer,can also be customized
PrecisionRSD ≤ 0.5
Gas ControlAutomatic gas control system
Lamp holder≤ 6 lamps automatic turret, automatic alignment
MeasurementFlame method, Hydride generation-Atomic absorption method
Sample Tray70 sample cups, 6 reagent cup
The ProgramAutomatic temperature control up to 20 order
Heating Modevertical heating
Power supply110 / 220 V (+5 % ~ (-10) %), 60 / 50 Hz; 5000 VA
Ignition TypeMicrocomputer control, automatic ignition
Print resultsPrint the final stages of test data or analysis. The results can be exported into Excel worksheet.
Sample Volume1 - 100 μl
Optical SystemLarge 1800 /mm grating ruling, full closed optical system
Detection Limit0.4 × 10-12g (Cd)
Absorbance Range0 - 4 A
Wavelength range180 – 900 nm
Temperature Rangeroom temperature to 3000 ℃
The Cooling WaterCan choose cooling water circulation system
Spectral Bandwidth0.1 nm,0.2 nm,0.4 nm, 1.0 nm, 2.0 nm automatic setting
Atomization ChamberPolymer explosion-proof spray chamber
Temperature ControlThe furnace enriched up to 20 times
Wavelength accuracy≤ 0.15 nm
Detection Limit (Cu)0.002 μg/mL
The volume of samplebetter than 1 %(at the time of 10 mL - 100 mL)
Characteristics Volume0.5 × 10-12g (Cd)
Lamp power supply modepulsed power supply
The Smallest Lincrement0.1 μl
Wavelength repeatability± 0.1 nm
Concentration calculationStandard curve method(1 - 3 times curve), automatic fitting
Temperature Control MethodVertical optical temperature monitoring graphite tube wall temperature
Repeated Sampling Frequencyup to 99 Times
Characteristic concentration (Cu)0.015 μg / mL / 1 %
Cleaning and waste container volumeEach 500 mL
The number of repeated measurements1 to 99, automatic calculation of average concentration, standard deviation, relative standard deviation.

Atomic Absorption spectrophotometer is used in scientific research, quality control, disease control, environmental protection, metallurgy, agriculture, chemical industry, and analysis of samples, equipment maintenance, simple and convenient.