[email protected]
+44 20 3371 7320 Mon - Sat: 9:00 AM - 6:00 PM
Home All Products Spectrophotometer Atomic Absorption Spectrophotometer LD-LAAS-A13
Atomic Absorption Spectrophotometer LD-LAAS-A13

Atomic Absorption Spectrophotometer LD-LAAS-A13

SKU: LD-LAAS-A13

Flame Atomic Absorption SpectrophotometerLD-LAAS-A13is a microprocessor controlled instrument based on analysis of metal ions by flame and graphite furnace atomizer with their absorption at wavelength of 190 to 900 nm. Czerny-Turner monochromator and variance of bandwidth provides user flexibility. It is provided with deuterium hollow cathode lamp to exclude interference of molecular absorption and Titanium Burner to increase the analysis efficiency and precision of flame. Its double beam radiation sources enables good basic line stability. Graphic analysis system provides data on analysis of entire process e.g. measured value, temperature, procedures, time, etc. It has great applications in research, medicine, environmental science and other industries.

  • ✓ Integrated flame/graphite furnace atomization system, changeable with flame emission burner
  • ✓ Turret for 8 pre-aligned Hollow Cathode Lamps fitted with pre-heating, and individual pre-centred lamps
  • ✓ PID and Dual curve mode light-controlled temperature control technique ensures fast heating and analytical sensitivity
  • ✓ Fully automated wavelength scanning and peak searching
  • ✓ Advance software for complete parameter settings
  • ✓ Reliable fully automatic graphite furnace analysis
  • ✓ Alarm feature to protect fuel gas leakage, abnormal flow, insufficient air pressure and abnormal flame extinction in flame system
  • ✓ Analysis of elements by flame absorption method and emission method
  • ✓ Strong database system which possesses more than 500 data self-storage
  • ✓ Results printed as parameter, data result and diagram
Also available in:
Wavelength range : 190 - 900 nm Wavelength range : 180 - 900 nm Wavelength range : 180 – 900 nm Wavelength range : 180 – 900 nm Wavelength range : 190 nm ~ 900 nm Working spectral range : 190 to 900 nm
Grating1800 lines / mm
AtomizerEfficient glass atomizer
InflamerAll-metal titanium burner
Dimensions700 × 550 × 450 mm
Net weight75 Kg
Lamp stand8 lamps automatic turret, automatic alignment
Power supply220 V ± 22 V AC
Protection systemCan inevitably cut off gas if pressure is low, power cut-off, flame out and alteration of the burner
Spectral Bandwith0.1, 0.2, 0.4, 1.0 and 2.0 nm
Baseline stability≤ 0.002 Abs / 30 min
Wavelength accuracy± 0.15 nm
Acetylene air burner100 mm
Characteristic viscocity≤ 0.025 μg / ml / 1 %
Wavelength repeatability≤ 0.04 nm
Working spectral range190 to 900 nm
Measurement Repeatability0.005
Detection limit of copper0.004 μg / ml
Ignition dynamic baseline drift≤ 0.006 Abs / 30 min
Standard deviation of the accuracy≤ 0.5 % (Cu, absorbance > 0.8 A) (detection limit Cu ≤ 0.008 μg / ml)
D2 Background calibration ability1 A ≤ 30 times correction ability
Characteristic concentration of copper0.02 μg / ml / 1 %
1.PC workstation
2.Printer
3.Oil free Air compressor
4.Acetylene reducing valve
5.Cu - Hollow cathode lamp
6.Air filter
GRAPHITE FURNACE
Maximum temperature3000 OC
Temperature increasing speed≥ 2000 OC / S
Characteristic quantity(Cd) ≤ 0.5 × 10 to 12g ,(Cu) ≤ 0.5 × 10 to 11g
Accuracy(Cu) ≤3 % , (Cd) ≤ 3 %
Dimension550 × 450 × 300 mm
Net weight65 Kg
Safety systemProtection for Overload current, reduced air pressure, low cooling water flow
Power supply220 V ± 22 V AC, 7000 W

It is suitable to analyse trace amount of element from mixture, also in forensics and chemistry, biological science to detect toxic elements from blood and drug samples.