[email protected]
+44 20 3371 7320 Mon - Sat: 9:00 AM - 6:00 PM
Home All Products Spectrophotometer Atomic Absorption Spectrophotometer LD-LAAS-A21
Atomic Absorption Spectrophotometer LD-LAAS-A21

Atomic Absorption Spectrophotometer LD-LAAS-A21

SKU: LD-LAAS-A21

Atomic Absorption spectrophotometer comes with flame, graphite furnace and hydride generation system to meet different customer demand. It consist of 1800/mm reticle large are grating monochromator and titanium burner to improve the analysis efficiency and accuracy of the flame. Atomic Absorption spectrophotometer has manual 3 lamp holder configuration & 3 independent lamp power supply for analysis.

  • ✓ 1800 /mm reticle (dispersion rate) large area grating monochromator
  • ✓ High performance hollow cathode lamp
  • ✓ Titanium burner for the flame analysis
  • ✓ Polymer automization chamber
  • ✓ Automatic analysis for sensitivity and reproducibility
  • ✓ High precision automatic optical system
  • ✓ Flame, graphite furnace operating mode can be switched automatically
  • ✓ Light source 3 lamp holder
  • ✓ Convenient data processing & sharing & printing
  • ✓ Powerful software with automatic instrument and additional control
Also available in:
Wavelength range : 190 - 900 nm Wavelength range : 180 - 900 nm Wavelength range : 180 – 900 nm Wavelength range : 180 – 900 nm Wavelength range : 190 nm ~ 900 nm Working spectral range : 190 to 900 nm
BurnerFull titanium combustion head, 50 mm or 100 mm general combustion head
NebulizerAtomizer efficient glass atomizer,can also be customized
PrecisionRSD ≤ 0.5 %
Gas ControlAutomatic gas control system
Lamp holder≤ 3 lamps automatic turret, automatic alignment
MeasurementFlame method, Hydride generation-Atomic absorption method
Ignition TypeMicrocomputer control, automatic ignition
Print resultsPrint the final stages of test data or analysis. The results can be exported into Excel worksheet.
Optical Systemlarge 1800 /mm grating ruling, full closed optical system
Absorbance Range0 - 4 A
Wavelength range180 – 900 nm
Atomization ChamberPolymer explosion-proof spray chamber
Wavelength accuracy≤ 0.15 nm
Detection Limit (Cu)0.002 μg/mL
Lamp power supply modepulsed power supply
Wavelength repeatability± 0.1 nm
Concentration calculationStandard curve method(1 - 3 times curve), automatic fitting
Characteristic concentration (Cu)0.015 μg / mL / 1 %
The number of repeated measurements1 to 99, automatic calculation of average concentration, standard deviation, relative standard deviation.

Atomic absorption spectrophotometer is widely used in analysis of elements from the mixture in scientific research, environmental science, metallurgy, agriculture & chemical industry, food, mining, and petrochemical, pharmaceutical industries.

Similar Products