Fast-speed microcomputer-controlled vertical autoclave with an eight-column mechanical interlocking system, automatic water feeding, cooling fan, drying mode, embedded steam collector, and selectable exhaust system. Equipped with a 0.2 μm PTFE biosafety exhaust filter (99.99% efficiency) to prevent biohazard aerosol release. Safety features include water level detection, overpressure, cooling lock, dry-burn protection, over-temperature protection, safety valve, chamber leakage protection, anti-scald design, and short-circuit protection.
SKU Code: LD-LVA-M12
| Capacity | 110L |
| Pressure | Max Working Pressure: 0.27 MPa; Design Pressure: 0.52 MPa |
| Dimension | 660 × 644 × 1180 mm |
| Controller | Fast-Speed Intelligent PID Controller |
| Cooling Fan | Built-in |
| Opening Way | Up & Down (Triple Safety Interlock) |
| Rated Power | 4600 W |
| Exhaust Mode | Automatic Internal Discharging with Steam Collecting Bottle; 6 Selectable Exhaust Speeds |
| Safety Device | Eight-column interlocking device, Electric double inner lock, Over-temperature protection, Temperature rise protection, Dry-burn protection, Water level sensor, Over-voltage protection, Safety valve, Closure check, Over-current protection, Short-circuit protection, Leakage protection, Cooling lock, Anti-scald protection, Fault detection, Timer, Temperature probe, Open-circuit detection, Exhaust check system |
| Display System | LED Screen |
| Steam Collector | Embedded 2 Steam Collectors |
| Chamber Material | SUS304 |
| Chamber Dimension | Ø400 × 895 mm |
| Cooling Lock Open | 40–80°C for Liquid Cycle, 40–99°C for Other Cycles |
| Drying (Optional) | Drying Time: 1–300 min, Drying Temperature: 80–140°C |
| Preset Timer Range | 1 min to 15 days |
| Printer (Optional) | Thermal Printer |
| Rated Power Supply | 220V, 32A, 50/60Hz |
| Sterilization Cycle | 1. Liquid 2. Liquid with Warming 3. Solid 4. Wrapped Instrument 5. Fabric 6. Rubber 7. Fast 8. Waste 9. Agar with Dissolving & Warming 10. Drying 11. User-defined (20 Cycles) |
| Warming Temperature | 45–79°C |
| Working Environment | 5–45°C, Relative Humidity 10%–85% |
| Pressure Gauge Range | -0.1 to 0.5 MPa |
| Temperature Accuracy | 0.1°C |
| Range of Warming Time | 1–9999 min |
| Dissolving Temperature | 60–115°C |
| Stainless Steel Basket | (Ø370 × 250) mm × 3 |
| Range of Dissolving Time | 1–6000 min |
| Sterilization Temperature | 105–138°C, Design Temperature: 152°C |
| Range of Sterilization Time | 1–6000 min |
| Widely used in the applications of Biochemistry, pharmaceutical industry, medicine and health care industry, Biotechnology, Microbiology and scientific research. |