Analytical-Instruments > Thermal-Cycler > Advanced-PCR-System > Real Time PCR LD-LRTP-B10
Features
- Ferrotec Peltier cooler with improved efficiency and long life
- Wide range of block temperature (4-105°C) with SOAK low temperature function
- 2 individual filters cover wide range of fluoresence detection wavelength
- Easy data transfer via USB and Bluetooth
- Real time fast double wavelength X-Y scan system
- High long life LED
- Dual high sensitivity PMT (photomultiplier tube) synchronous detection
- Panoramic view of experimental results
Real Time PCR LD-LRTP-B10
Real time PCRLD-LRTP-B10comes with 96 well capacity PCR machine with, 1 to 36°C gradient temperature range, and fast speed dual colour scanning mode. Its wide fluorescence wavelength range with innovative 2 channel design, optimizes thermal performance and maximizes convenience during operation. With its unique block dissipation technology, it provides precise temperature control and thermal gradient which easily optimizes PCR assays.
SKU Code: LD-LRTP-B10
Also Available in below capacities
Sample Capacity : 12 × 8 (96 wells with 0.2 ml each) plate, 96 × 0.2 ml tubes (Bottom Transparent)
Sample Capacity : 96-Well PCR plate12 × 8-strip
96 × 0.2 ml(Bottom Transparent)
96 × 0.2 ml(Bottom Transparent)
Sample Capacity : 96-Well PCR plate12 × 8-strip
96 × 0.2 ml(Bottom Transparent)
96 × 0.2 ml(Bottom Transparent)
Sample Capacity : 96-Well PCR plate12 × 8-strip
96 × 0.2 ml(Bottom Transparent)
96 × 0.2 ml(Bottom Transparent)
Sample Capacity : 48 × 0.2 ml
Sample Capacity : 48 × 0.2 ml
- Specifications
- Product Applications
| Socket | RS 232C Adapter |
| Program | Max 20 Segments for Each Program, Max 99 Cycles |
| Scan Mode | Entire Plate or Designated Line |
| Scan Period | 5.5 sec |
| Power Supply | 100 to 240 V, 50/60 Hz, 600 W |
| Ramping Rate | 4.0 ℃/sec |
| Dynamics Range | 10 to 1010 Copies |
| Operation Mode | Continuous |
| PC Configuration | Memory : 512 M; Hard Disk : 10 GB; CPU : Pentium® 4; Virtual Memory : ≥ 1000 MB |
| Temp. Uniformity | ≤ ± 0.3 ℃ |
| Block Temp. Range | 4 to 105℃ (Minimum Increment: 0.1℃), SOAK Low Temp. Conservation Function |
| Temp. Fluctuation | ≤ ± 0.1 ℃ |
| Temp. Control Mode | BLOCK/Tube Simulation Mode (Automatic Control based On Sample Volume ) |
| Emission Wavelength | 500 to 800 nm |
| Hot-lid Temp. Range | 30 to 110℃ (Adjustable, default 105℃, Automatic Hot-lid ) |
| Sample Volume Range | 5 to 100μl |
| Gradient Temp. Range | 1 to 36 ℃ |
| Excitation Wavelength | 300 to 800 nm |
| Temp. Control Accuracy | ≤ ± 0.1 ℃ |
| Detected Fluorescence | F1 : FAM, SYBR Green 1; F2 : VIC HEX TET JOE |
| Dimension ( L × W × H ) | 430 x 395 x 352 mm |
| Max. channels number of fluorescence detection | 2 channels |
| Real time PCR, used in quantification and characterization of nucleic acids in academic institutes, research centres, diagnostics and laboratories. |