Analytical-Instruments > Spectrophotometer > Nano-Spectrophotometer > Table top spectrophotometer LD-LTS-A10
Features
- Top port caliber
- 5 inch TFT touch screen
- Round shaped quartz plates for measurement
- SCS system for best measurement repeatability
- Simultaneous SCE & SCI measurement
- 8°/diffused illumination geometric design of lightning
- Connection to mini printers for printing
- High capacity rechargeable lithium-ion battery
- UDB, PC software for data transmission, storage
Table top spectrophotometer LD-LTS-A10
Table top spectrophotometerLD-LTS-A10is a high performance spectrophotometer with test caliber (top port) upward. The solid samples (paper sheets, cloth) can be placed directly on the measurement port & particles like pellets, tablets, powder (dye, food powder, chemical powder), paste (thick paste, opaque samples can be placed in a round shape plates & then in the mouth of the measurement unit. It is adopted with every test calibration ETC technology, where the standard white boards is included in the optical system for reliable, accuracy of every measurement.
SKU Code: LD-LTS-A10
Also Available in below capacities
Illumination system : d/8 (Diffused lighting, 8° observation angle)
SCS optical engine (light splitting and integration system)
ETC (real time calibration technology )
SCI (specular reflection included) & SCE(specular reflection excluded)simultaneous measurement
SCS optical engine (light splitting and integration system)
ETC (real time calibration technology )
SCI (specular reflection included) & SCE(specular reflection excluded)simultaneous measurement
Illumination system : d/8 (Diffused lighting, 8° observation angle)
SCS optical engine (light splitting and integration system)
ETC (real time calibration technology )
SCI (specular reflection included) & SCE(specular reflection excluded)simultaneous measurement
SCS optical engine (light splitting and integration system)
ETC (real time calibration technology )
SCI (specular reflection included) & SCE(specular reflection excluded)simultaneous measurement
Illumination system : d/8 (Diffused lighting, 8° observation angle)
SCS optical engine (light splitting and integration system)
ETC (real time calibration technology )
SCI (specular reflection included) & SCE(specular reflection excluded)simultaneous measurement
SCS optical engine (light splitting and integration system)
ETC (real time calibration technology )
SCI (specular reflection included) & SCE(specular reflection excluded)simultaneous measurement
Illumination system : d/0 (Diffused lighting, 0° observation viewing), SCS optical engine (light splitting and integration system), ETC (ever
- Specifications
- Product Applications
| Sensor | Dual light path sensor array |
| Weight | 4.5 kg |
| Display | 5.5 inch TFT touch screen |
| Interface | USB |
| Color space | CIE-L*a*b, L*C*h, L*u*v, XYZ, Yxy, Reflectance, hunterlab, munsell Mi, CMYK |
| Data storage | 20000 test results |
| Light source | A, C, D50, D65, D75, F1, F2, F3, F4, F5, F6, F7, F8, F9, F10, F11, F12, DLF, TL183, TL184, NBF, U30, CWF |
| UV light source | Not included |
| Battery capacity | Rechargeable, 20000 continuous tests, 7.4V/6000mAh |
| Measurement time | 1 s |
| Wavelength range | 400-700 nm |
| Dimension (L*W*H) | 350 × 300 × 200 mm |
| Observation Angle | 2°/10° |
| Measuring aperture | 11 mm |
| Half spectral width | 5 nm |
| Wavelength interval | 10 nm |
| Data being displayed | SPD distribution/data,sample's color values,color difference values/graph,pass/fail results,color error tendency,color simulation display measurement area,history data color simulation,manual input standard sample generate measurement report |
| Color matching system | Matches |
| Light source longevity | 10 years, 3 million tests |
| Work temperature range | 0 to 45℃, relative humidity 80% or below( at 35°C ),no condensation |
| Illumination light source | CLED |
| Measurement time interval | 0.5 s |
| Size of integrated sphere | 40 mm, alvan diffused reflection surface coating |
| Storage temperature range | 25℃ to 55℃ relative humidity 80% or below(at 35°C ),no condensation |
| Reflectivity range & resolution | 0 to 200%, 0.01% |
| The top port table top spectrophotometer can measure color of solid samples such as particles, powder, paste, pellets, opaque liquids used in textile, medicine, chemical, food, paper & other industries. |