Features

  • A closed system comprised automated Chemiluminescent Immunoassay Analyzer
  • 60 samples position and 30 reagent positions with 50 incubation positions
  • Magnetic particle separation technology and magnetic particle enzymatic chemiluminescence principle
  • Random, Batch and STAT operation modes with 80 T/H throughput rate
  • 15 to 100 µl sample volume and 6/7 points calibration system with 28 days stability
  • Washing and mixing module with three-level cleaning mode, ensures efficient cleaning
  • Sample probe with intelligent anti-collision system and liquid level detection system
  • 18 min time to 1st result with CV ≤ 5% of detection precision, ensures good consistency
  • WIN 7/8/10 software system with bi-direction and HL7 protocol support
  • Different advanced functions, allows high-sensitive and faster reaction speed
  • Intelligent alarm prompt, to ensure high-efficient, stable and reliable results
  • TCP/IP Network interface, provides end-to-end communications and easy modification

Chemiluminescent Immunoassay Analyzer LD-LCIA-A10

Chemiluminescent Immunoassay Analyzer LD-LCIA-A10 is a closed system comprised automated unit, offers 60 samples position and 30 reagent positions with 50 incubation positions. Adopted with magnetic particle separation technology and magnetic particle enzymatic chemiluminescence principle, features Random, Batch and STAT operation modes and 80 T/H throughput with 15 to 100 µl sample volume and 6 to 7 points calibration system. Equipped with washing and mixing module and sample probe, offers 18 min time to 1st result with CV ≤ 5% of detection precision. Designed with WIN 7/8/10 software system with bi-direction and HL7 protocol support, has different advanced functions and intelligent alarm prompt along with TCP/IP network interface.

SKU Code: LD-LCIA-A10

Also Available in below capacities

Software Bi-direction, HL7 protocol support
Functions Liquid level detection Anti-collision function Sample barcode scanning Reagent radio frequency identification
Interface TC/IP network interface
Principle Magnetic particle enzymatic chemiluminescence
Net Weight 130 kg
Throughput 80 T/H
Alarm System Intelligent alarm prompt
Gross Weight 180 kg
Power Supply AC 110/220 V, 50/60 Hz
Sample Volume 15 to 100 µl
1stResult Time 18 mins
Carry-over Rate ≤ 10 to 5
Operation Modes Random, Batch and STAT
Sample Position 60 (Each position could be used as an emergency position)
Calibration Type 6/7 points calibration
Reagent Position 30 (2 to 8°C Refrigeration)
Separation Method Magnetic particle separation technology
Detection Precision CV ≤ 5%
Dimension (W×D×H) 1120×735×513 mm
Incubation Position 50
Calibration Stability 28 days
Software Compatibility WIN 7/8/10, 32 or 64 bits
Correlation Coefficient r ≥ 0.99
Packaging Dimension (W×D×H) 1303×873×854 mm
Chemiluminescent Immunoassay Analyzer is used for selective, sensitive, rapid and simple analysis and to detect a large number of complicated or low-abundance samples across environmental monitoring, clinical diagnosis, food safety and pharmaceutical analysis etc.