[email protected]
+44 20 3371 7320 Mon - Sat: 9:00 AM - 6:00 PM
Home All Products Autoclaves Cassette Autoclave LD-LCA-A10

Cassette Autoclave LD-LCA-A10

SKU: LD-LCA-A10

Cassette Autoclave provides rapid and reliable sterilization for non-wrapped instruments, making it ideal for multi-department operations and emergency situations. Its intuitive digital interface allows for real-time monitoring, with the added flexibility to safely interrupt cycles when necessary. The ultra-thin cassette design accelerates heating and cooling, optimizing workflow efficiency, and making it a perfect solution for workrooms, medical facilities, and high-demand environments.

  • ✓ Delivers fast and dependable sterilization results
  • ✓ Completes non-wrapped sterilization cycles in 9 minutes
  • ✓ Simple and intuitive operation with a clear on-screen interface
  • ✓ Automatic fault detection system with shutdown and on-screen error notifications
  • ✓ Suitable for both hollow and solid instruments
  • ✓ Ultra-Slim cassette design enhances thermal efficiency for quicker processing
  • ✓ Fitted with a 0.22-micron filter for effective filtration of microorganisms
  • ✓ Cycle interruption is supported for added operational flexibility
  • ✓ Reduced cycle duration boosts productivity
  • ✓ Structured five-phase cycle: Displacement, Heating, Sterilization, Exhaust and Drying
  • ✓ Monitors and records the sterilization process in real-time
  • ✓ Equipped with a built-in printer for automatic documentation
WaterUltra-pure water, deionized water, laboratory water, distilled water, purified water.
Run ModeRun Intermittently (≤6 cycles/hour)
Input Power≤1.3 kVA
Tank Volume3.4 Litres
Power SupplyAC 220 V±22 V, 50 Hz ± 1 Hz
Display Accuracy0.1 ℃
External Dimension580 x 460 x 190 mm
Sterilization Time9 minutes
Sterilization VolumeAbout 5.2 Litres
Steam Generator Power1.2 kVA ± 5%
Equipment Working MediumWater Vapor
Operating Pressure Range42 kPa ~ 212 kPa
Ambient Temperature Range+ 5 °C ~ + 40 °C
Working Relative Humidity≤85%
Atmospheric Pressure Range70.0 kPa to 106.0 kPa
Maximum Operating Pressure242 kPa
Sterilization Chamber Size380 x 180 x 78 mm
Operating Temperature Range115 °C – 135 °C
Maximum Operating Temperature138 °C
Safety Valve Setting Pressure0.25 MPa
Sterilization External Box Size480 x 196 x 80 mm

Ideal for use in dental clinics, medical clinics, emergency rooms, surgical centres, ENT and endoscopy departments, laboratories, veterinary clinics, and instrument processing workrooms.