XRD DiffractometerLD-LXRD-A10contains tube current up to 5 to 80 mA with a dimension 1 × 10 mm/ 0.4 × 14 mm/ 2 × 12 mm and are designed for quality diffraction data, combined with ease of use and flexibility to quickly switch to different applications, This multipurpose diffractometers are all equipped with X-ray tuble of glass tube, ceramic tube, ripple ceramic tube with many different X-ray source materials (Cu, Fe, Co, Cr and Mo) and is coupled with an auto-switching dual wavelength optic. It have Low maintenance, high performance system and designed with Horizontal Goniometer structure and proportional/Scintillation counters detector.
| Weight | About 25 kg |
| Detector | Proportional/Scintillation counters |
| Dimension | 1100 × 850 × 1750 mm |
| Stability | ≤ 0.01 % |
| Focus Size | 1 × 10 mm/ 0.4 × 14 mm/ 2 × 12 mm |
| Rated Power | 3 kW |
| X-ray Tuble | Glass tube, Ceramic tube, Ripple Ceramic tube: Cu, Fe, Co, Cr, Mo etc., Power 2 kW |
| Tube Current | 5 to 80 mA |
| Tube Voltage | 10 to 60 kV |
| Scanning Mode | Ø to 2 Ø linkage, Ø, 2 Ø single action; continuous/stepping scanning |
| Scanning Range | 0 to 164 |
| Scanning Speed | 0.0012º to 70 º min |
| Counting Fashion | Differential Coefficient / integral, PHA automatically, Dead time regulate |
| Scattered Rays Dose | ≤ 1 µ Sv/h (without X-ray protective device) |
| Goniometer Structure | Horizontal (Ø to 2 Ø ) |
| Radius of Diffraction | 185 mm |
| Minimal Stepping Angle | 1 / 1000 º |
| Energy Resolution Ratio | ≤ 25 % (PC), ≤ 50 % (SC) |
| Maximum Resolving Speed | 100 º / min |
| Angle Repeatable Accuracy | 1 / 1000 º |
| Stability of System measure | ≤ 0.01 % |
| Instrument Integrative Stability | ≤ 0.5 % |
| Maximum Counting rate of Linearity | 5 × 105 CPS (with the compensate function of dropout counting) |
Best suited for the research and industrial product analysis with perfect combination of conventional analysis crucial measurement product and for academics and researchers in different application areas.
Atomic Fluorescence Spectrometer LAFS-A10
✓ Beam Configuration : Dual Channel
✓ Elements ( Measuring Range ) :
As, Se, Pb, Bi, Sb, Te, Sn
< 0.01 µg/L
Hg, Cd
< 0.001 µg/L
Zn
< 1.0 µg/L
Ge
< 0.1 µg/L
Angular Spectrometer LASM-A10
✓ Angle Measurement Accuracy : 1inch
FTIR Spectrometer LIR-A10
✓ Spectral Range : 7800 to 350cm-1
✓ Resolution : Better than 0.85cm-1
FTIR Spectrometer LIR-B10
✓ Spectral Range : 7800 cm-1 to 350 cm-1
✓ Resolution : 0.85 cm-1
ICP spectrometer LICP-A10
✓ Wavelength range ( 3600 lines / mm ) : 180 to 500 nm
✓ Wavelength range ( 2400 lines / mm ) : 180 to 800 nm