ICP SpectrometerLD-LICP-B10is an instrument which measures elements in ppb levels with least interference and reduces the time taken for analysis by detecting 5 to 6 elements in 1 min. Excellent analytical precision, high optical resolution, fully automated, wide wavelength range with 2400 line grating, powerful analysis software, high performance solid-state RF system, high accuracy etc. are some of the characteristic features. The equipment consist of a Scott-type spray chamber, quartz torch, spectrophotometer with Czerny-Turner monochromator, detector with photomultiplier tube and data processing system which allows multi-element measurement along with high resolution. It finds applications in environmental, food safety, metallurgy, pharmaceutical etc. fields.
| Humidity | ≤ 70% |
| Resolution | ≤ 0.015nm (3600 line grating) ≤ 0.030nm (2400 line grating) |
| Test speed | 5 to 8 elements / min |
| Temperature | 15°C to 30°C |
| Focal length | 1000 mm |
| Output power | 800 W to 1600 W, adjustable with power efficiency more than 65% |
| Other Details | |
| Repeatability | short-term stability- RSD ≤ 1.5% Long-term stability: RSD ≤ 2% |
| Spray chamber | Scott double pass spray chamber |
| Induction coil | 25 mm × 3 ID (ID-internal diameter), equipped with three concentric quartz torch tubes 35 mm ED (ED-external diameter) |
| Control Circuit | |
| Power Stability | 220 ± 10V; 50 to 60 V |
| Wavelength range | 195 to 500 nm for 3600 line grating 195 to 800 nm for 2400 line grating |
| Signal acquisition | VF conversion |
| Working Environment | |
| Negative high voltage | -50 to -1000 V |
| Grating specifications | huge holographic grating with 3600 L/mil or 2400 L/mil and 80 mm × 100 mm of ruling area |
| Output power stability | ≤ 0.05% |
| Circuit measuring range | (10-12 to 10 -4) A |
| Technical Specifications | |
| Monochromator Specifications | |
| Solid State Power Specifications | |
| Humidity for storage and transportation | ≤ 70% |
| Limits of detection (LOD, µg/L) for most elements | 1ppb to 10ppb |
It used for quantitative and qualitative analysis of elements in the given sample. Various fields like petrochemicals, pharmaceuticals, agriculture, environmental, food industry, metallurgy, processing industry etc. require it for several operations.
Atomic Fluorescence Spectrometer LAFS-A10
✓ Beam Configuration : Dual Channel
✓ Elements ( Measuring Range ) :
As, Se, Pb, Bi, Sb, Te, Sn
< 0.01 µg/L
Hg, Cd
< 0.001 µg/L
Zn
< 1.0 µg/L
Ge
< 0.1 µg/L
Angular Spectrometer LASM-A10
✓ Angle Measurement Accuracy : 1inch
FTIR Spectrometer LIR-A10
✓ Spectral Range : 7800 to 350cm-1
✓ Resolution : Better than 0.85cm-1
FTIR Spectrometer LIR-B10
✓ Spectral Range : 7800 cm-1 to 350 cm-1
✓ Resolution : 0.85 cm-1
ICP spectrometer LICP-A10
✓ Wavelength range ( 3600 lines / mm ) : 180 to 500 nm
✓ Wavelength range ( 2400 lines / mm ) : 180 to 800 nm