Ion chromatograph systemLD-LICS-A22with cation and anion dual channel design, independently operates and simultaneously detects both channels without disturbing each other. Temperature controlled bipolar conductivity detector, improves the detection performance and stability of the instrument. System is comprised of an auto sampler, anion and cation suppressor.
| Power | 150 W |
| HS code | 9027201200 |
| Flow range | 0.001 to 9.999 ml/ min |
| Net weight | 48 kg |
| Cell volume | ≤ 0.8 µl |
| Flow system | |
| Control mode | By Stepper motor |
| Gross weight | 73 kg |
| Linear range | ≥ 103 |
| Power supply | DC 220 V, 60 Hz |
| Column heater | |
| Six way valve | PEEK material pressure 5000 psi, independent automatic collection and flow function |
| Vacuum degree | (-) 70 kPa |
| Detection mode | Bipolar conductivity detection |
| Flow stability | (0.2 to 0.5) ml/ min ≤ 3 % , (0.5 to 1.0) ml/ min ≤ 2 %, > 1.0 ml/ min ≤ 2 % |
| Output voltage | -6000 to +6000 mV (adjustable) |
| Pressure pulse | ≤ 0.5 % |
| Detection range | 0 to 50000 µS/ cm |
| Internal volume | 30 µl |
| Degassing device | |
| Eluent generator | |
| Flow rate change | 0.1 to 3.0 ml/ min |
| Maximum pressure | 20 MPa |
| Minimum pressure | 5 MPa |
| Maximum flow rate | 10 ml/ min |
| External dimension | 500 × 500 × 760 mm |
| Degassing efficiency | 10 ml/ min 90 % |
| Instrument linearity | ≥ 0.999 |
| Operating temperature | Room temperature 5 to 60°C ( 41 to 140°F) |
| Temperature stability | ≤ 1°C/ h |
| Concentration increment | 0.1 mM |
| Ion Chromatographic pump | |
| Display pressure accuracy | ≤ 0.1 MPa |
| Qualitative repeatability | ≤ 1.0 % |
| Eluent concentration range | 0.1 to 100 mM |
| Quantitative repeatability | ≤ 1.0 % |
| Contact material of the rotor | PEEK |
| Controlling temperature accuracy | ± 0.01°C |
| Thermal buffer system for Eluent | |
| Numerical control and electromagnetic injection | |
| Allowable deviation of column heater temperature | ± 2°C |
| Digital temperature and control detection system |
Used to detect small molecules (in the form of anion, cation) in water testing & processing plants, food, chemical and dye industry, mining, metallurgy, and other fields.
Gas Chromatography LGC-B11
✓ Oven :
Maximum capacity
22 L
Temperature range
RT + 5 ℃ to 400 ℃
Temperature accuracy
± 0.1 ℃
Temperature program
9-phase/ 10 platform
Gas chromatography mass spectrometry GC-MS-879
Ion Chromatograph LPIC-A10
Ion chromatograph system LICS-A20
Ion chromatograph system LICS-A21
✓ Ion Chromatographic Pump :
Type
High pressure and low pulse double plunger tandem advection pump
Maximum pressure
35 MPa (PEEK)
Pressure display accuracy
≤ 0.1 MPa
Flo