Touch Thermal Cycler (Gradient) LD-LTCG-A12
SKU: LD-LTCG-A12Touch Thermal Cycler (Gradient)LD-LTCG-A12with customized 8 pcs long service life Marlow (US) peltier heating units. With 5°C/s maximum ramping rate, this cycler saves operation time of user. Its 8 inch TFT touch screen with graphical real time display. With Windows OS, PC control function, print function, large storage capacity, USB connection, this cycler meets latest experimental demands.
- ✓ 8” TFT color screen for easy monitoring
- ✓ High heating and cooling rate
- ✓ Step less adjustable hot lid with pressure protection
- ✓ Built in in 11 standard program file template for quick editing of files
- ✓ Real time display to show running status of experiment
- ✓ One-click quick incubation function to meet different experimental needs
- ✓ Internal flash memory for 10000 typical PCR files
- ✓ User-friendly setting for hot lid temperature and hot lid work mode
- ✓ Auto restart after power failure
- ✓ Easy view of actual and target temperatures in real time
- ✓ Support USB and LAN to update software
- ✓ Supports email alert function when experiment is over
Also available in:
Capacity : 96 × 0.2 ml
Capacity : 60 × 0.5 ml
Capacity : 384 well
Capacity : 96 × 0.2 ml
Capacity : 60 × 0.5 ml
Capacity : Double (each block with) 48×0.2ml
| LCD | 8 inch,800×600 Pixels, 16 colors TFT touch screen |
| Yes | |
| Weight | 8.5 kg |
| Program | 10000+(USB FLASH) |
| Capacity | 384 well |
| Cooling Rate | 4 ℃/s |
| Heating Rate | 5 ℃/s |
| Power Supply | 85 to 264 V AC , 47 to 63 Hz , 600 W |
| Communication | USB 2.0 , LAN |
| Pause Function | Yes |
| Gradient Spread | 1 to 30℃ |
| Max No. of Steps | 30 |
| Gradient Accuracy | ≤ ± 0.2 ℃ |
| Max No. of Cycles | 99 |
| Gradient Unformity | ≤ ± 0.2 ℃ |
| Auto Data Protection | Yes |
| Dimension ( L×W×H ) | 380 × 240 × 260 mm |
| Temperature Uniformity | ≤ ± 0.2 ℃ |
| Block Temperature Range | 0 to 100℃ |
| Ramping Rate Adjustable | 0.1 to 5℃ |
| Temperature Control Mode | Block \ Tube |
| Time Increment/Decrement | 1 sec to 9 min 59 sec |
| Hot Lid Height Adjustable | Stepless Adjustable |
| Hot-lid Temperature Range | 30 to 110℃ |
| Gradient Temperature Range | 30 to 100℃ |
| Temperature Control Accuracy | ≤ ± 0.1 ℃ |
| Temperature Increment/Decrement | 0.1 to 9.9℃ |
Widely used in advanced PCR applications across research and development, animal and plant tissue culture, food science, pharmaceuticals, life science, and analytical laboratories.
Similar Products
Touch Thermal Cycler (Basic) LTCB-A10
✓ Capacity : 96 × 0.2 ml
✓ Block Temperature Range : 0 to 100℃
Touch Thermal Cycler (Basic) LTCB-A11
✓ Capacity : 60 × 0.5 ml
✓ Block Temperature Range : 0 to 100℃
Touch Thermal Cycler (Basic) LTCB-A12
✓ Capacity : 384 well
✓ Block Temperature Range : 0 to 100℃
Touch Thermal Cycler (Basic) LTCB-A13
✓ Capacity : 3 × (32 × 0.2 ml )
✓ Temperature Range : 0 to 100℃
Touch Thermal Cycler (Gradient) LTCG-A10
✓ Capacity : 96 × 0.2 ml
✓ Block Temperature Range : 0 to 100℃